• Увеличить размер шрифта
  • Размер шрифта по умолчанию
  • Уменьшить размер шрифта

defaultКомпрессоры в жившемся смазанный жиром

б/у компрессоров
Equipment Pictures Synairgies ссылка ИзготовительмодельПотокмощность ( киловатт )давлениеГодПолный часЧас в грузесерийный номеранглийский описаниеEmail
20041
COMPAIR
L250 RS
41,41
250
7,5
2007


349031 / 0647

17038
SULLAIR
AirOne160
25,2
160
8
2007
40 301
36 384
71116 0024

17039
SULLAIR
AirOne160
25,2
160
8
2008
30 000
28 000
71116 0028

19172
KAESER
DSD281
25,8
160
7,5
2003
45 000
29 863
1004
Tested on 22-09-2020: OK || |needs service
19173
KAESER
DSD281
25,8
160
7,5
2003
46 533
32 730
1003
Tested on 15-09: Ok
19174
KAESER
DSD281 for parts
25,8
160
7,5
2003
46 000

1005
Motor and screw element turning || |Missing: Sigma control, suction head, transformer, coupling, pressure sensor
18003
WORTHINGTON
RLR180 A5
25,3
132
7,5
1997


415824 203644 .02
running until 2018-08 - not tested
19123
KAESER
DSDX243 SFC
20,12
132
12
2012
40 000

DSDX.2 1157

19124
WORTHINGTON
RLR180 A6
20,7
132
10,5
2003
60 000

WCO 150754
Checkup on 12/05/2020 done without motor: OK , careful, emergency stop cuts 230V without giving information to the control pannel NEEDS REWIRING
14053
WORTHINGTON
RLR150
18,8
110
8
1999
67 825
37 119
WCO 150104

19086
COMPAIR
L110
18
110
7,5
2003
62 456

349021 / 0679
Tested on 14-09: OK || |Screw element replaced at 30000 hours + Motor revision + Requalification R
19070
WORTHINGTON
RLR150 A5

110

1996



with Elektronikon Mk4
19056
INGERSOLL RAND
R110i
13,73
110
14
2015
1 257
210
UCV1008768
Tested on the 14-09: OK
20003
ATLAS COPCO
G110

110
8,5
2013
49 536
38 827
WUX 408365
Tested on 21-09-2020: OK
20004
ATLAS COPCO
G110

110
8,5
2013
38 785
11 139
WUX 408366
Tested on 21-09-2020: OK
19071
WORTHINGTON
RLR125 AE6 EAU WATER
15,16
90
8
2001
42 303
37 422
WCO 550711

19090
INGERSOLL RAND
R90iu
16,7
90
7,5
2008
8 488
2 064
5340048
Tested on 14-09: OK
20000
KAESER
CSDX162

90
8
2004
44 746
20 042
1013
Tested on 22-09-2020: OK || |Screw element changed at 36548 hours
20008
ATLAS COPCO
GA90
18
90
7,5
2003
75 102
40 379
AIF 081356

20010
ATLAS COPCO
GA90
18
90
7,5
2006
78 235
74 144
AIF 106465
Inlet valve missing.
20011
ATLAS COPCO
GA90 for parts

90
7,5
1997


AIF 039889
For parts
19088
WORTHINGTON
RLR100
14,3
75
8
2004


WC0551809

14167
INGERSOLL RAND
ML75
13,6
75
7,5
1998
35 750
14 745
2340433
Tested on 19/07/2019: Intellys battery to be replaced. Resets on factory mode once network off
19065
SULLAIR
AIRONE 75
14
75
7
2008
63 500
56 950
71275037
Checkup motor and screw element are OK
19153
COMPAIR
L75 SR
12,2
75
13
2002
50 767

F170-0989
Tested on 28/05: Compressor needs service
14145
INGERSOLL RAND
ML55
9,6
55
7,5
1995
49 001
42 226
78910
Run test the 07/01/2015 - This machine is in good condition, it is however necessary to require a "flexible hose", and there is a oil leak.
14253
INGERSOLL RAND
MH55
8,2
55
10
1997
60 000


Tested on 15/07/2019: Good state, was rented for 200h in 2018
17054
SULLAIR
BDS55
8,92
55
8
2004
31 326
21 617
6958
Teste don 08-03-19: OK
19087
WORTHINGTON
RLR75
10,2
55
8
2001




14071
INGERSOLL RAND
MH55
8,2
55
10
1995
69 487
41 459
78922
Last test was made on 18/05/2015, the machine works altogether rather well, but there are some problems : Oil leak on injection flexible / Condensate leak on the precipitatot / Motor compressor unit of origin.
13409
WORTHINGTON
RLR75 RollAIR75
9,5
55
8
1995
62 916

391157
Run test the 19/05/2014: OK | Screw air end Creyssensac
18006
COMPAIR
L55
10,69
55
7,5
2004
62 977
29 876
349029 / 0029
Tested on 13-11: Air end year 2008
19138
ATLAS COPCO
GA55 ff
10,2
55
7,5
2008
11 127
63 127

Tested on the 22-04-2020: Compressor is working, screw element changed once (11000h since). Dryer not working
19097
COMPAIR
L45
7,87
45
7,5
2004
54 142
39
3490022/1721
Tested on 03/03/20: OK
19084
KAESER
BS60
5,25
37
10
1986
29 514
16 744
501903

19106
COMPAIR
L37
6,17
37
10
2004



Tested on 19/05/2020: Running machine but noisy screw element
19151
WORTHINGTON
RLR4000
5,3
30
8
1998
51 119
14 175
WCO 100464

14344
MAUGUIERE
MAV190
2,6
15
8
2001
12 740

CAI 027132
Tested on the 08/08/2016: default on thermostaic valve - needs global service
19131
ATLAS COPCO
GA15
168,8
15
8
2000


AII 249468
oil leak around the separator flexible. Hour counter is missing || |tested on the 25/08/2020
19185
WORTHINGTON
RLR20
2,75
15
8
2009
36 768
20 721
CAI382332
Tested on 07-09: OK
19187
ATLAS COPCO
GX7 FF
0,84
7,5
7,25
2002


AII623120
Tested on 25/08 - Leak on radiator of oil cooler
Please check the availibility of product before ordering.
Prices indicated are net prices in Euro and valid for compressed air distributors only as having the knowledge of the technical use and of their local regulation concerning compressed air equipment.
Electrical Compressors are all for usage on 380Volt or 400 Volt/3/50Hz - Otherwise indicated in comments.
Product are sold in state. Not tested otherwise indicated in comments. Not included : packing, shipping, duty, freight, Installation, commissioning, garanties.
We can not warranties the constructors data (pressure-flow) and number of hours. 100 % payment with the order by transfer bank.
Others conditions following our General Terms and Condisitons.
SARL SYNAIRGIES, 54 rue Ernest Macarez, F-59300 Valenciennes - Limited liability company with the capital of 7500 Euros - RCS of Lille - SIRET : 51431412900032 - VAT:FR65514314129

поиск


последние возможности

Liste des compresseurs d'occasion